Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Standardized Supplier Management
The company established and implemented an effective suppliers' assessment procedure and corrective & preventive actions mechanism
to see all verified strength labels (15)
  • Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
  • Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
  • Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
  • Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
  • Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
  • Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
Find Similar Products

Basic Info.

Model NO.
14kw
Work Environment
Low-temperature Heat Pump
Heat Source
Air-source + Water-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
Nominal Cooling Capacity
14kw
Nominal Heating Capacity
16kw
Copc
2.99, 3.38
Rated Input Power
4.68, 4.73
Lplv(C)
4.5
Circulating Water Flow(M3/H)
2.41
Maximum Total Power(Kw)
7.3
Maximum Operating Current(a)
34
Refrigerant
R290, R410A
Water Resistance(Kpa)
20
Net Weight
119kg
Refrigeration Operation
5~55
Heating Operation
-30~43
Transport Package
Wooden Shelf Packaging
Specification
980*390*1260
Trademark
YANGGUANG
Origin
Hebei, China.
HS Code
8418612090
Production Capacity
500000 Sets Per Year.

Packaging & Delivery

Package Size
220.00cm * 86.00cm * 86.00cm
Package Gross Weight
200.000kg

Product Description

Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
Model/Paremeter TFCA120BEDNC TFCA140BEDNC TFCA160BEDNC TFCA180BERNA TFCA200BERNA TFCA220BERNA TFCA255BERNA TFCA285BERNA TFCA335BERNA
Power 220V~50Hz                                                                                          380V 3N~50Hz
Nominal cooling capacity 7ºC kW 12 14 16 18 20 21 25.5 28.2 32
Rated input power(kW) 3.77 4.68 5.4 6.04 6.89 7.72 7.5 8.41 10.6
COPc(kW/kW) 3.18 2.99 2.96 2.98 2.9 2.72 3.4 3.35 3.02
Nominal heating capacity 45ºC kW 14 16 18 20 22 22.5 27 30 34
Rated input power(kW) 4.09 4.73 5.37 6.1 6.77 7.25 7.4 8.33 9.99
COPh(kW/kW) 3.42 3.38 3.35 3.3 3.25 3.1 3.65 3.6 3.4
LPLV(C) 4.6 4.5 4.3 4.5 4.4 4.3 4.95 4.94 4.6
Circulating water flow(m3/h) 2.06 2.41 2.75 3.1 3.44 3.61 4.39 4.9 5.5
Maximum total power(kW) 7.3 10 14.5 17 17.5
Maximum operating current(A) 34 16.5 24 26 27
Applicable ambient temperature(ºC) Refrigeration operation 5~55 -5~55
Heating operation -30~43 -30~55
Refrigerant/Filling amount R410A/2.80kg R410A/3.85kg R410A/6.30kg
Operation sound(dB(A)) 55 55 56.5 57 57 57.5 56 58 59
Water resistance(kPa) 16 20 26 26 30 32 15 20 25
Circulating water pipe connection Inlet/outlet pipe diameter DN32
Connection External thread(R 1-1/4') External thread(R 1-1/4'')
Net weight 119 140 205
Size 980*390*1260 1100*470*1550
Products can be widely used in centralized heating, process hot water, breeding, hotels and other places. The lowest heating operation loop temperature can reach -32ºC; the highest water temperature can reach 60ºC; YangGuang ultra-low loop temperature air source heat pump heating unit, only for customers to bring more professional heating solutions!
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
1. Energy efficiency - heat pumps transfer heat instead of generating it, which makes them more efficient than traditional heating systems that use fuel or electricity to generate heat.
2. Lower operating costs - you can save money on your energy bills because the system is more efficient.
3. Low carbon emissions - because heat pumps do not use fossil fuels, they produce fewer carbon emissions than conventional heating systems.
 
4. Low maintenance costs - air source heat pumps require less maintenance than other heating systems, making them more cost effective in the long run.
5. Flexibility - Air source heat pumps can be used for both heating and cooling, providing year-round comfort.
6. Improved indoor air quality - As air source heat pumps do not burn fuel, they do not produce fumes, making them a healthier option for your home.
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China

Split Air Source Heat Pump for Hotel HVAC System Fabricado Da ChinaSplit Air Source Heat Pump for Hotel HVAC System Fabricado Da ChinaThe coldest coal mine in China, Datong, Shanxi Province, the winter temperature reaches -35 ºC, the use of YangGuang electric company's air-source heat pump from the mine lack of wind in the absorption of low-grade heat, through the water-source heat pumps and electric boiler auxiliary heating, for the system to provide a steady stream of 50 ºC constant temperature hot water, so as to achieve the inlet wellhead anti-freezing insulation purposes, air-source heat pumps and water-source heat pumps, as well as the electric boiler, the Trinity of the joint operation of the system, to solve the problem of the mine's high energy consumption, but also for the China's carbon neutrality and the cause of the peak of the carbon to make its due contribution.
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
The purchase of products comes with a mysterious little gift from China
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da ChinaSplit Air Source Heat Pump for Hotel HVAC System Fabricado Da ChinaSplit Air Source Heat Pump for Hotel HVAC System Fabricado Da ChinaQ1: Are you a manufacturer or trading company?

A: We are a professional manufacturer of electric boilers with over 20 years of experience.

Q2: What is your sample policy?

A: Our sample fee is refundable and the sample fee can be refunded through your bulk order.

Q3: What is the production lead time?

A: For stock models, lead time is 7-15 days after payment.

Q4: Do you provide technical support?

A: Of course, we can provide you with corresponding pictures and videos.
Split Air Source Heat Pump for Hotel HVAC System Fabricado Da China

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier